Tell us about your device

The device, what it touches and for how long, and your date. That is enough for an expert to tell you which tests are likely and how long they take.

Loading the form…

What we do, in the order it runs

  • 1. The plan

    A biological evaluation plan to ISO 10993-1:2025. It sorts each part of your device by what it touches and for how long, uses the data you already hold, and lists only the tests that are left. First draft in about two weeks.

    Biocompatibility evaluation

  • 2. The testing

    We write the protocols, place each test at an ISO/IEC 17025 accredited laboratory we have qualified, track the samples and review every result before it reaches you.

    Test subcontracting

  • 3. The assessment

    Chemical characterization to ISO 10993-18 and a toxicological risk assessment to ISO 10993-17, signed by a board-certified toxicologist. Together in 9 to 11 weeks; an assessment on data you already hold in 2 to 3.

    ChemTox™

How long each test takes, and how many devices it needs

Weeks run from the day the laboratory receives your samples. Devices are for one example, thin-walled solid, 17.09 cm² per device, each test sized on its own with a 15% buffer. A program is the sum of its tests, so the seven-test example needs 138. The 28-day and 90-day studies take a fresh extract on every dosing day, which is why they need so many devices and why chemistry with a toxicological risk assessment often answers them. Implantation is counted in specimens, not devices.

TestStandardWeeksDevices
Biological tests
CytotoxicityISO 10993-52 to 35
SensitizationISO 10993-108 to 1033
IrritationISO 10993-237 to 95
Material-mediated pyrogenicityISO 10993-11, USP <151>8 to 937
Acute systemic toxicityISO 10993-116 to 710
Subacute toxicity, 28 daysISO 10993-1110 to 12451
Subchronic toxicity, 90 daysISO 10993-1122 to 262,691
Genotoxicity, AmesISO 10993-3, OECD 4716 to 721
Genotoxicity, mouse lymphomaISO 10993-3, OECD 49012 to 1337
Implantation, 13 weeksISO 10993-622 to 24, with histologyBy specimen
Chemical characterization
Elemental analysis (ICP-MS/OES)ISO 10993-184 to 55
Volatile organic compoundsISO 10993-184 to 55
Semi-volatiles (GC/MS), per solventISO 10993-184 to 52
Non-volatiles (HPLC/MS), per solventISO 10993-184 to 52
Size it for your device

The calculator is free with an account.

Hemocompatibility, other implantation periods and tests not listed here are in the catalog, each with its own turnaround.

Who you would be working with

More than 75
device companies served, directly and through partners
More than 100
safety documents delivered: plans, reports and risk assessments
7 qualified laboratories
3 in the United States, 3 in India, 1 in Germany. Every one qualified by us; none is our own.

Counts as of November 2026.

7 laboratories, each one qualified

We own no laboratory, and we do not collect them. A laboratory runs nothing for us until it has been through our supplier qualification (ISO 13485, clause 7.4), and it is re-evaluated under the same procedure. The list is short on purpose.

The performing laboratory's ISO/IEC 17025 certificate and scope come with your estimate, or on request.

  • 3

    United States

    ISO/IEC 17025 accredited and qualified by Groenakker.

  • 3

    India

    ISO/IEC 17025 accredited and qualified by Groenakker. Each has direct experience of successful FDA submissions.

  • 1

    Germany

    ISO/IEC 17025 accredited and qualified by Groenakker.

Questions people ask first

Which ISO 10993 tests does my device need?

It depends on what each part touches and for how long. ISO 10993-1:2025 lists the biological effects to evaluate for each kind of contact, and existing data comes before new tests. A biological evaluation plan settles the list for your device. Tell us the device and its contact and an expert will name the likely tests on the first call.

How long does biocompatibility testing take?

Cytotoxicity takes 2 to 3 weeks, irritation 7 to 9 and sensitization 8 to 10, counted from the day the laboratory receives your samples. The table on this page gives each common test. A program runs as long as its longest test, plus the plan before it and the report after it.

How many devices do I have to send?

Extracts are sized by surface area, so it depends on the size and wall thickness of the device and on the tests. The table on this page shows the count for one example device. The sample size calculator in the free account works it out for yours.

What does it cost?

We do not publish prices. You get an estimate in writing after a short call, or you can pick your tests in the free account and send the list for pricing. Prices appear in the account within one business day, once we confirm your company.

Do you run the tests yourselves?

No. Groenakker is not a laboratory. The tests run at 7 accredited laboratories in the United States, India and Germany that we have qualified. Our experts write the protocol, review every result and issue the report under our ISO 13485:2016 certified quality system.

Will this get my device cleared?

No one can promise a regulator's decision. We build the evaluation to the current standard and the agency's guidance, sign it, and answer the questions that come back.

Ready when you are

Send the device and your date and an expert replies within one business day. Or open a free account and see which tests your device calls for before you talk to anyone.

Or call +1 (888) 682-7993, Monday to Friday, 8am to 4pm ET.