Regulatory updates
What changed, who it affects and what to do, with the sources and the day we checked them.

- 20 Dec 202625 days leftCurrentUS
FDA stops accepting ISO 10993-17:2002 declarations on 20 December 2026
After 20 December 2026, FDA will not accept declarations of conformity to ISO 10993-17:2002. Cite the 2023 edition under recognition 2-303 and note its exclusions.
Affects: US premarket submissions (510(k), De Novo, PMA) that cite ISO 10993-17
Read the update - 20 Nov 2026CurrentUSSafety alert
Safety alert: two hydrophilic-coating removals in one month put coating integrity in the evaluation
Arrow International (10 November) and Heraeus Medical Components (20 November) removed hydrophilic-coated guidewires after coatings swelled unevenly in saline and shed particles. Neither was an extractables finding.
Affects: Coated intravascular devices (guidewires, PICCs, stylets) and their biological evaluations
Read the update - 10 Nov 2026CurrentUSEU
EN ISO 10993-6:2026 and EN ISO 10993-7:2026 are MDR-harmonised
Decision (EU) 2026/2479 lists the 2026 editions of Parts 6 and 7 as harmonised under the MDR for the first time. FDA still recognizes the 2016 and 2008 editions.
Affects: EU MDR technical documentation; implantation and EO residual data in EU files; IVDR files using radiation sterilization
Read the update - 2 Nov 2026CurrentCA
Health Canada updates its recognized standards list: ISO 18562 added, a note on ISO 10993-1:2025
Health Canada's list of recognized standards, effective 2 November 2026, adds ISO 18562-1 to -4 for breathing-gas pathways and notes that devices under clause 6.5.11.2 of ISO 10993-1:2025 may need testing beyond that clause.
Affects: Canadian medical device licence applications; breathing-gas pathway devices
Read the update - 7 Sep 2026CurrentUS
What FDA excludes from ISO 10993-18, and why the GC uncertainty factor of 2 is out
FDA's recognition 2-298 of ISO 10993-18:2020 with Amd 1:2022 excludes Table D.3 and the Annex E text that offers an uncertainty factor of 2 for GC screening. Each method needs its own justified factor.
Affects: Chemical characterization reports and AET derivations in US submissions
Read the update - 24 Aug 2026CurrentUS
FDA recognizes ISO 10993-1:2025; 2018 declarations accepted until 1 July 2029
Recognition List 066 replaced 2-258 (2018 edition) with 2-313 (2025 edition, partial). The 2018 edition stays acceptable until 1 July 2029, and FDA's September 2023 guidance is unchanged.
Affects: Every US submission that declares conformity to ISO 10993-1; biological evaluation plans in progress
Read the update - 6 Aug 2026CurrentUS
ISO 10993-3:2026 is published; FDA still recognizes the 2014 edition and TR 33
The fourth edition moves Part 3 toward evaluation and absorbs the TR 33 test guidance. For US declarations the recognized documents are still ISO 10993-3:2014 (2-228) and ISO/TR 10993-33:2015 (2-243).
Affects: Genotoxicity, carcinogenicity and reproductive toxicity endpoints; declarations of conformity in US submissions
Read the update
Key dates
What ends, and when
Add to your calendar (.ics)| Date | What happens |
|---|---|
| FDA stops accepting declarations of conformity to ISO 10993-17:2002 (recognition 2-237). Read the update → | |
| ICH Q3E revised Step 3 draft expected (a pharmaceutical guideline, not a device requirement); Step 4 expected July 2027. | |
| EN ISO 11137-1:2015 and EN ISO 14155:2020 references withdrawn from the MDR and IVDR harmonised lists. Read the update → | |
| FDA stops accepting declarations of conformity to ISO 10993-1:2018 (recognition 2-258). Read the update → |
The Groenakker Brief
Every update, once a month, in one email
Each item in one line, with what to do and a link to the full update. No sales copy. Unsubscribe any time.